CIC-D160+ with Built-in Eluent Generator
Shine
The CIC-D160+ is a compact and intelligent single-channel ion chromatograph, featuring a built-in eluent generator for precise routine analyses. Reliable, secure, and fully automatable, it is ideally suited for applications requiring high stability and sensitivity.
The CIC-D160+ is an enhanced version of the D160, equipped with a built-in eluent generator. When paired with an autosampler and ShineLab software, it allows unattended injection for up to 24 hours.
Advantages
- Built-in eluent generator :
Automatically produces hydroxide or methanesulfonic acid-based eluents, allowing for isocratic or gradient elution modes.
- Real-time suppressor and column monitoring :
Ensures timely replacement of critical consumables, maintaining the system’s accuracy and stability.
- Baseline correction and filtering algorithm in software:
Efficiently corrects baseline drift and reduces background noise, especially during gradient elution.
- Integrated safety alarms :
Alerts for pressure issues, liquid leakage, and wash solution levels; the system shuts down automatically in case of leakage.
- Auto-ranging conductivity detector :
Expands signal range from ppb to ppm automatically, without manual range adjustment.
- Built-in gas-liquid separator :
Effectively eliminates bubble interference for more stable analysis results.
- Scheduled auto-start function :
The system can be programmed to start in advance, enabling the operator to begin testing upon arrival.
- Built-in vacuum degasser :
Removes bubbles from the eluent, improving stability and reliability of test results.
The CIC-D160+ single-channel ion chromatograph is designed for intelligent, stable, and highly accurate conductivity detection, either with or without a suppressor and with or without an autosampler. Its integrated eluent generator ensures high-performance, automated analysis with gradient elution capability. Ideal for applications across environmental, pharmaceutical, food and beverage, and chemical industries.
Channel(s) | 1: Anions ou Cations |
Pump | Flow Rate Range 0.001~12mL/min |
Autosampler | Optional: SHA D9 14mL×96 / SHA 18i With automatic dilution function 120 vial, 2ml (standard) 48 vial, 5ml (Optional) 30 vial, 7ml (Optional) 30 vial, 10ml (Optional) |
Built-in Eluent Generator (Standard) | Eluent Types KOH/NaOH/LiOH/MSA Eluent Concentration Range 0.1-100mM Flow Rate Range 0.1-5.0mL/min |
Column Heater | Ambient + 5 to 85 ℃ |
Conductivity Detector | Type Auto-range conductivity detector Cell Volume ≤0.4μL Detection Range 0~50000 µS/cm Baseline Noise ≤0.0002μS/cm Baseline Drift ≤0.001μS Temperature Range Ambient +5℃~60℃ Instrument Linearity ≥0.999 Minimum Detectable Concentration Cl-≤0.0001ug/mL Li+≤0.0001ug/mL |
Suppressor | Self-Regeneration electrolytic micro-membrane suppressor |
- Environment
- Petrochemicals
- Food & Beverage (Water, soft drinks…)
- Energy
- Batteries
- Cosmetics
- Textiles
- Ionic Pesticides
- Chemical Industry
- Pharmaceuticals
- Mining
- Electronics and Semiconductors…