CIC-D260 Dual
Shine
The CIC-D260 is a compact and high-performance dual-channel ion chromatograph, designed for the simultaneous detection of anions and cations. With its intelligent interface and broad compatibility, it meets the demanding requirements of modern laboratories.
The CIC-D260 is a third-generation dual-channel ion chromatograph. It not only enhances detection efficiency but also provides users with an unmatched user experience.
Advantages
- Dual-channel design allows simultaneous detection of anions and cations.
- Compact format optimizes space usage within the laboratory.
- New bipolar pulse detector directly extends the concentration range from ppb to ppm without requiring manual adjustment.
- Intelligent alarm system includes alerts for leakage, residual eluent, low pressure, and high pressure.
- Real-time monitoring of consumable wear, with a clear display of component status.
- Built-in gas-liquid separator effectively eliminates the influence of bubbles on the system.
- Compatible with a wide range of usage scenarios : in addition to traditional conductivity detectors (CD), it supports other detector types such as ECD, UV, DAD, ICP, MS, etc.
Whether you work in environmental monitoring, food analysis, chemical production, or in the development and quality control of pharmaceuticals, the CIC-D260 will meet your practical needs thanks to its outstanding performance and remarkable reliability.
Channel(s) | 2: Anions et Cations Simultanés |
Pump | Flow Rate Range 0.001~9.999mL/min |
Autosampler | Optional: SHA D9 14mL×96 / SHA 18i With automatic dilution function 120 vial, 2ml (standard) 48 vial, 5ml (Optional) 30 vial, 7ml (Optional) 30 vial, 10ml (Optional) |
Built-in Eluent Generator (option) | Eluent Types KOH/NaOH/LiOH/MSA Eluent Concentration Range 0.1-100mM Flow Rate Range 0.1-5.0mL/min |
Column Heater | Ambient + 5 to 60 ℃ |
Conductivity Detector | Type Auto-range conductivity detector Cell Volume ≤0.8μL Detection Range 0~50000 µS/cm Baseline Noise ≤0.005μS/cm Baseline Drift ≤0.005μS Temperature Range Ambient +5℃~60℃ Instrument Linearity ≥0.999 Minimum Detectable Concentration Cl-≤0.0004ug/mL Li+≤0.0001ug/mL |
Suppressor | Self-Regeneration electrolytic micro-membrane suppressor |
- Environmental monitoring
- Petrochemical analysis
- Food and beverage quality control (water, drinks, etc.)
- Energy and battery sectors
- Cosmetics
- Textile industry
- Ionic pesticides
- Chemical and pharmaceutical industries
- Mining
- Electronics and semiconductor components…